Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Volume Laboratory

Force Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


FORCE Universal testing machine
Tensile testing machine
BS EN ISO 7500-1 : 2004

On-site

-10N to 100N    
-50N to 500N    
-100N to 1000N    
-1kN to 5kN    
-5kN to 10kN    
-10kN to 22.5kN    
-22.5kN to 225kN    
FORCE Universal testing machine
Compression testing machine
In-house method direct measuring with stand weight

In-house

-10N to 100N    
-50N to 500N    
-100N to 1000N    
-1kN to 5kN    
-5kN to 10kN    
-10kN to 22.5kN    
-22.5kN to 225kN    
-225kN to 2000kN    
FORCE Push pull gauge, Dial and Digital Force gauge (Tension) In-house method based on ISO7500-1

In-house

-100gf to 1000gf    
-1kgf to 10kgf    
-5kgf to 50kgf    
-10kgf to 100kgf    
FORCE (Compression)    
-100gf to 1000gf    
-1kgf to 10kgf    
-5kgf to 50kgf    
-10kgf to 100kgf    
FORCE Force transducer with indicator    
-10N to 250kN    

Dimension Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


DIMENSION External micrometer
0 mm to 25 mm
JIS B7502 : 1994

In-house

Vernier, dial and digital Caliper
0 mm to 300 mm
JIS B7507 : 1993 In-house
Dial or digital thickness gauge
0 mm to 10 mm
In-house method based on JIS B7503 : 1992 In-house
Dial or digital thickness gauge
>10 mm to 50 mm
In-house method based on JIS B7503 : 1992 In-house
Height gauge
0 mm to 300mm
In-house method based on JIS B7517 : 1993 In-house/On-site

Height gauge

0 mm to 600mm

In-house method based on JIS B7515 : 1982 In-house/On-site
  Bore gauge
0.001 mm to 100mm
In-house method based on JIS B7503 : 1997 In-house
Dial gauge and digital indicator
0 mm to 1 mm
>1 mm to 25 mm
JISB 7184 : 1999 (Clause4) On-site
  Profile projector
X-Axis 0 mm to 200 mm
JISB 7153 : 1995 (Clause4)  
  Y-Axis 0 mm to 200 mm JISB 7516 : 2005 On-site
  Measuring microscope
0 mm to 200 mm
>200 mm to 300 mm
In-house method based on ISO9513 : 1999 In-house
  Steel ruler / Steel tape
0 mm to 1000 mm
In-house method based on ISO5893 : 2002
In-house method by
comparison to standard
stop watch
On-site
  Extensometer
Type clip on
Up to 50 mm
JIS B 7506 : 1997,
ISO 3650
On-site
  Type long travel
Up to 1000 mm
JIS B 7524 : 1992 On-site
 

Crosshead and actuator speed

1 mm/min up to 1000 mm/min

JIS B 7420 : 1997 In-house
  Gauge block (grade 0,1,2)
1 to 100 mm
JIS B 7420 : 1997 In-house
  Feeler gauge
0 to 5 mm
JIS B 7420 : 1997 In-house
  Snap gauge
Up to 100 mm
JIS B 0261 (M), EA-10/10 In-house
  Pin gauge
Up to 200 mm
EA-4/20 In-house
  Plain Plug gauge
Up to 200 mm
JIS B 0261 (M), EA-10/10 In-house
  Thread plug gauge
M1 to M68
JIS B 3301 : 1989 In-house
  Plain Ring gauge
0.5 mm to 200 mm
JIS B 3310 : 1989 In-house
  Thread ring gauge
3 mm to M68
JIS B 3310 : 1989,
EA-10/10
In-house
  Taper Plain Plug gauge
All size
JIS B 3310 : 1989,
EA-10/10
In-house
  Taper Plain Ring gauge
M3 to 200 mm
  In-house
  Taper Thread Plug gauge
All size
  In-house
  Taper Thread Ring gauge
M3 to 200 mm
  In-house

Mass & Balance Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


MASS Electronic balance
Up to 10g
In-house method based on
UKAS Lab14 : 2006

In-house

>10g to 20g    
>20g to 50g    
>50g to 100g    
>100g to 200g    
>200g to 1000g    
>1kg to 10kg    
>10kg to 1000 kg    
  Electronic balance
Up to 40g
In-house method based on
UKAS Lab14 : 2006

On-Site

>40g to 100g    
>100g to 200g    
>200g to 400g    
>400g to 1kg    
>1kg to 3kg    
>3kg to 6kg    
>6kg to 10kg    
>10kg to 30kg    
>30kg to 60kg    
>60kg to 150kg    
>150kg to 300kg    
>300kg to 500kg    
>500kg to 1000kg    
MASS Conventional mass class F1 In-house method based on
OIML R111-1 : 2004

In-house

  1 mg
   
  2 mg    
  5 mg    
  10 mg    
  20 mg    
  50 mg    
  100 mg    
  200 mg    
  500 mg    
  1 g    
  2 g    
  5 g    
  10 g    
  20 g    
  50 g    
  100 g    
  200 g    
  500 g    
  Conventional mass class F1 In-house method based on
OIML R111-1 : 2004

In-house

  1 kg    
  2 kg    
  5 kg    
  10 kg    
  20 kg    

Temperature Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


TEMPERATURE Temperature controlled chamber
Up to 50°C
TLAS G-20-1/02-08(E)

On-site

>50°C to 100°C

   

>100°C to 150°C

   

>150°C to 200°C

   

>200°C to 250°C

   

Digital thermometer with probe
50°C to 650°C

In-house method based on comparison technique In-house
/On-site
 

Autoclave 50°C to 100°C
>100 °C to 150 °C

In-house method based onBS2646 part 5 : 2001 On-site
  Water bath 5 °C to 100°C In-house method based on ASTM E715-80 : 2001 On-site

Torque Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


TORQUE Torque Wrench
Clockwise
ISO6789 : 2003

In-house

  0 N.m to 100 N.m
0 N.m to 500 N.m
0 N.m to 1000 N.m
   
  Anticlockwise    
  0 N.m to 100 N.m
0 N.m to 500 N.m
0 N.m to 1000 N.m
   
  Torsion Tester In-house method base on
ISO6789 : 2003
On-site
  1 N.m to 1000 N.m    
       
       

hardness Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


HARDNESS Hardness Durometer n-house method base on ASTM D2240

In-house

 

Shore A

   
 

Shore B

   
 

Shore E

   
 

Shore O

   
 

Shore C

ISO6508 - 2 On-site
 

Shore D

   
 

Shore DO

ISO6506 - 2 On-site
 

Rockwell hardness tester HRA, HRB, HRC

   
  Brinell Hardness tester
1kgf to 3000kgf
   

Pressure Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


PRESSURE Pressure gauge
0 to 700 bar
DKD R6-1

In-house/On-site

Pressure transmitter
0 to 700 bar
In-house method In-house/On-site
Vacuum gauge
Up to 1 bar
In-house method In-house/On-site
Absolute pressure gauge Up to 760 mmHg In-house method In-house

Electrical Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


ELECTRICAL Force Indicator
-4mV/V to 4 mV/V
In-house method

In-house

  Digital Multimeter
DC Voltmeter
0 V to 1000 V
Comparison with Multi-Product Calibrator In-house/On-site
  AC Voltmeter
0 V to 1000 V
  In-house/On-site
  DC Ammeter
0 A to 19.9999 A
  In-house/On-site
  AC Mmmer
0 A to 19.9999 A
  In-house/On-site
  Ohm Meter
0 to 330 mΩ
  In-house/On-site
  Capacitance meter
330 pF to 1100 mF
  In-house/On-site
  Analog Multimeter
DC Voltmeter
0 V to 1000 V
Comparison with Multi-Product Calibrator In-house/On-site
  AC Voltmeter
0 V to 1000 V
  In-house/On-site
  DC Ammeter
0 A to 19.9999 A
  In-house/On-site
  AC Mmmer
0 A to 19.9999 A
  In-house/On-site
  Ohm Meter
0 to 330 mΩ
  In-house/On-site
  Capacitance meter
330 pF to 1100 mF
Comparison with Multi-Product Calibrator In-house/On-site
  Digital Multimeter (<5 ½ digit) Comparison with Multi-Product Calibrator In-house/On-site
  Frequency Generator
( <1 x 10-5 Period)
0 to 300 Mhz
Comparison with Multi-Product Calibrator In-house/On-site
  Frequency Generator
(>1 x 10 -5 Period)
0 to 300 Mhz
Comparison with Multi-Product Calibrator In-house/On-site
  RF meter, Power meter
(Single Phase)
11 kW
Comparison with Digits
Multimeter and Multi-
Product Calibrator
In-house/On-site
  AC/DC Calibrator
DC Voltage Source
10 mV to 1000V
  In-house/On-site
  AC Voltage Source
10 mV to 1000V
  In-house/On-site
  DC Current Source
0.1 mA to 20A
  In-house/On-site
  AC Current Source
10 mA to 20A
  In-house/On-site
  Resistance Source
0Ω to 2 GΩ
  In-house/On-site
  Frequency Source
0 to 300 mMHz, 0 to 1.35 KHz
Comparison with Multi-Product Calibrator In-house/On-site
  Temperature recorder
(Input, Output : mV, Ohm)
Comparison with Multi-Product Calibrator In-house/On-site
  Temperature calibrator
(Input, Output : mV, Ohm)
Comparison with Multi-Product Calibrator In-house/On-site
  AC/DC wattmeter (Single phase)
Digital 11 kw
Analog 11 kw
Comparison with Multi-Product Calibrator In-house/On-site

Plastic & Rubber Tester Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


TESTING MACHINE Melt Flow Indexer
In-house method base on ASTM D1238 and ISO1133

On-site

  - Temperature Up to 300 C
- Die
Length & Outside diameter Up to 10 mm
- Piston
Diameter
Up to 10 mm
   
  - Weight of Piston
Up to 110 g
- Head of Length
Up to 7 mm
- Reference mark
Up to 30 mm
-Weight
Up to 10 kg
-Time
Up to 180 sec
In-house method base on ASTM D648 and ASTM D1525 On-site
  HDT-Vicat Tester
- Temperature
- Dimension
- Weight Set
- Temp Rate
- Displacement Reading
In-house method base on ASTM F2029 On-site
  Heat Seal Tester
- Temperature
- Pressure
- Timer
In-house method base on
ASTM D1894
On-site
  Friction Tester
- Sled weight
- Load cell
- Speed
In-house method based on
ISO13802 : 1999
On-site
  Pendulum Impact
-Velocity
-Angle
   

Chemical Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


CHEMICAL pH meter
Nominal pH
In-house method base on
ASTM E70-07

In-house

  4
7
10
   

Volume Laboratory

Field of
Measurement

Parameter/Range/Item

Standard/Technic Method
Equipment/Remark

Laboratory status
In-house/on-site


VOLUME Micro pipette Up to 100μl In-house method base on ISO 8655-6 : 2002 (E)

In-house

>100μl to 200μl    
>200μl to 500μl    
>500μl to 1000μl    
>1000μl to 5000μl    
>5000μl to 10000μl    
       
  Volumetric flask
1ml to 2000ml
In-house method base on
ASTM E542 :2001
In-house
  Mechanical metrology
instruments
   
MECHANICAL Viscometer (Dynamicrotation)
In-house method by
comparison with certified
viscosity standard
In-house
  100 cps
500 cps
5000 cps