Force Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
FORCE | Universal testing machine Tensile testing machine |
BS EN ISO 7500-1 : 2004 | On-site |
-10N to 100N | |||
-50N to 500N | |||
-100N to 1000N | |||
-1kN to 5kN | |||
-5kN to 10kN | |||
-10kN to 22.5kN | |||
-22.5kN to 225kN | |||
FORCE | Universal testing machine Compression testing machine |
In-house method direct measuring with stand weight | In-house |
-10N to 100N | |||
-50N to 500N | |||
-100N to 1000N | |||
-1kN to 5kN | |||
-5kN to 10kN | |||
-10kN to 22.5kN | |||
-22.5kN to 225kN | |||
-225kN to 2000kN | |||
FORCE | Push pull gauge, Dial and Digital Force gauge (Tension) | In-house method based on ISO7500-1 | In-house |
-100gf to 1000gf | |||
-1kgf to 10kgf | |||
-5kgf to 50kgf | |||
-10kgf to 100kgf | |||
FORCE | (Compression) | ||
-100gf to 1000gf | |||
-1kgf to 10kgf | |||
-5kgf to 50kgf | |||
-10kgf to 100kgf | |||
FORCE | Force transducer with indicator | ||
-10N to 250kN |
Dimension Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
DIMENSION | External micrometer 0 mm to 25 mm |
JIS B7502 : 1994 | In-house |
Vernier, dial and digital Caliper 0 mm to 300 mm |
JIS B7507 : 1993 | In-house | |
Dial or digital thickness gauge 0 mm to 10 mm |
In-house method based on JIS B7503 : 1992 | In-house | |
Dial or digital thickness gauge >10 mm to 50 mm |
In-house method based on JIS B7503 : 1992 | In-house | |
Height gauge 0 mm to 300mm |
In-house method based on JIS B7517 : 1993 | In-house/On-site | |
Height gauge 0 mm to 600mm |
In-house method based on JIS B7515 : 1982 | In-house/On-site | |
Bore gauge 0.001 mm to 100mm |
In-house method based on JIS B7503 : 1997 | In-house | |
Dial gauge and digital indicator 0 mm to 1 mm >1 mm to 25 mm |
JISB 7184 : 1999 (Clause4) | On-site | |
Profile projector X-Axis 0 mm to 200 mm |
JISB 7153 : 1995 (Clause4) | ||
Y-Axis 0 mm to 200 mm | JISB 7516 : 2005 | On-site | |
Measuring microscope 0 mm to 200 mm >200 mm to 300 mm |
In-house method based on ISO9513 : 1999 | In-house | |
Steel ruler / Steel tape 0 mm to 1000 mm |
In-house method based on ISO5893 : 2002 In-house method by comparison to standard stop watch |
On-site | |
Extensometer Type clip on Up to 50 mm |
JIS B 7506 : 1997, ISO 3650 |
On-site | |
Type long travel Up to 1000 mm |
JIS B 7524 : 1992 | On-site | |
Crosshead and actuator speed 1 mm/min up to 1000 mm/min |
JIS B 7420 : 1997 | In-house | |
Gauge block (grade 0,1,2) 1 to 100 mm |
JIS B 7420 : 1997 | In-house | |
Feeler gauge 0 to 5 mm |
JIS B 7420 : 1997 | In-house | |
Snap gauge Up to 100 mm |
JIS B 0261 (M), EA-10/10 | In-house | |
Pin gauge Up to 200 mm |
EA-4/20 | In-house | |
Plain Plug gauge Up to 200 mm |
JIS B 0261 (M), EA-10/10 | In-house | |
Thread plug gauge M1 to M68 |
JIS B 3301 : 1989 | In-house | |
Plain Ring gauge 0.5 mm to 200 mm |
JIS B 3310 : 1989 | In-house | |
Thread ring gauge 3 mm to M68 |
JIS B 3310 : 1989, EA-10/10 |
In-house | |
Taper Plain Plug gauge All size |
JIS B 3310 : 1989, EA-10/10 |
In-house | |
Taper Plain Ring gauge M3 to 200 mm |
In-house | ||
Taper Thread Plug gauge All size |
In-house | ||
Taper Thread Ring gauge M3 to 200 mm |
In-house |
Mass & Balance Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
MASS | Electronic balance Up to 10g |
In-house method based on UKAS Lab14 : 2006 |
In-house |
>10g to 20g | |||
>20g to 50g | |||
>50g to 100g | |||
>100g to 200g | |||
>200g to 1000g | |||
>1kg to 10kg | |||
>10kg to 1000 kg | |||
Electronic balance Up to 40g |
In-house method based on UKAS Lab14 : 2006 |
On-Site |
|
>40g to 100g | |||
>100g to 200g | |||
>200g to 400g | |||
>400g to 1kg | |||
>1kg to 3kg | |||
>3kg to 6kg | |||
>6kg to 10kg | |||
>10kg to 30kg | |||
>30kg to 60kg | |||
>60kg to 150kg | |||
>150kg to 300kg | |||
>300kg to 500kg | |||
>500kg to 1000kg | |||
MASS | Conventional mass class F1 | In-house method based on OIML R111-1 : 2004 |
In-house |
1 mg |
|||
2 mg | |||
5 mg | |||
10 mg | |||
20 mg | |||
50 mg | |||
100 mg | |||
200 mg | |||
500 mg | |||
1 g | |||
2 g | |||
5 g | |||
10 g | |||
20 g | |||
50 g | |||
100 g | |||
200 g | |||
500 g | |||
Conventional mass class F1 | In-house method based on OIML R111-1 : 2004 |
In-house |
|
1 kg | |||
2 kg | |||
5 kg | |||
10 kg | |||
20 kg |
Temperature Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
TEMPERATURE | Temperature controlled chamber Up to 50°C |
TLAS G-20-1/02-08(E) |
On-site |
>50°C to 100°C |
|||
>100°C to 150°C |
|||
>150°C to 200°C |
|||
>200°C to 250°C |
|||
Digital thermometer with probe |
In-house method based on comparison technique | In-house /On-site |
|
Autoclave 50°C to 100°C |
In-house method based onBS2646 part 5 : 2001 | On-site | |
Water bath 5 °C to 100°C | In-house method based on ASTM E715-80 : 2001 | On-site |
Torque Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
TORQUE | Torque Wrench Clockwise |
ISO6789 : 2003 |
In-house |
0 N.m to 100 N.m 0 N.m to 500 N.m 0 N.m to 1000 N.m |
|||
Anticlockwise | |||
0 N.m to 100 N.m 0 N.m to 500 N.m 0 N.m to 1000 N.m |
|||
Torsion Tester | In-house method base on ISO6789 : 2003 |
On-site | |
1 N.m to 1000 N.m | |||
hardness Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
HARDNESS | Hardness Durometer | n-house method base on ASTM D2240 |
In-house |
Shore A |
|||
Shore B |
|||
Shore E |
|||
Shore O |
|||
Shore C |
ISO6508 - 2 | On-site | |
Shore D |
|||
Shore DO |
ISO6506 - 2 | On-site | |
Rockwell hardness tester HRA, HRB, HRC |
|||
Brinell Hardness tester 1kgf to 3000kgf |
Pressure Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
PRESSURE | Pressure gauge 0 to 700 bar |
DKD R6-1 |
In-house/On-site |
Pressure transmitter 0 to 700 bar |
In-house method | In-house/On-site | |
Vacuum gauge Up to 1 bar |
In-house method | In-house/On-site | |
Absolute pressure gauge Up to 760 mmHg | In-house method | In-house |
Electrical Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
ELECTRICAL | Force Indicator -4mV/V to 4 mV/V |
In-house method |
In-house |
Digital Multimeter DC Voltmeter 0 V to 1000 V |
Comparison with Multi-Product Calibrator | In-house/On-site | |
AC Voltmeter 0 V to 1000 V |
In-house/On-site | ||
DC Ammeter 0 A to 19.9999 A |
In-house/On-site | ||
AC Mmmer 0 A to 19.9999 A |
In-house/On-site | ||
Ohm Meter 0 to 330 mΩ |
In-house/On-site | ||
Capacitance meter 330 pF to 1100 mF |
In-house/On-site | ||
Analog Multimeter DC Voltmeter 0 V to 1000 V |
Comparison with Multi-Product Calibrator | In-house/On-site | |
AC Voltmeter 0 V to 1000 V |
In-house/On-site | ||
DC Ammeter 0 A to 19.9999 A |
In-house/On-site | ||
AC Mmmer 0 A to 19.9999 A |
In-house/On-site | ||
Ohm Meter 0 to 330 mΩ |
In-house/On-site | ||
Capacitance meter 330 pF to 1100 mF |
Comparison with Multi-Product Calibrator | In-house/On-site | |
Digital Multimeter (<5 ½ digit) | Comparison with Multi-Product Calibrator | In-house/On-site | |
Frequency Generator ( <1 x 10-5 Period) 0 to 300 Mhz |
Comparison with Multi-Product Calibrator | In-house/On-site | |
Frequency Generator (>1 x 10 -5 Period) 0 to 300 Mhz |
Comparison with Multi-Product Calibrator | In-house/On-site | |
RF meter, Power meter (Single Phase) 11 kW |
Comparison with Digits Multimeter and Multi- Product Calibrator |
In-house/On-site | |
AC/DC Calibrator DC Voltage Source 10 mV to 1000V |
In-house/On-site | ||
AC Voltage Source 10 mV to 1000V |
In-house/On-site | ||
DC Current Source 0.1 mA to 20A |
In-house/On-site | ||
AC Current Source 10 mA to 20A |
In-house/On-site | ||
Resistance Source 0Ω to 2 GΩ |
In-house/On-site | ||
Frequency Source 0 to 300 mMHz, 0 to 1.35 KHz |
Comparison with Multi-Product Calibrator | In-house/On-site | |
Temperature recorder (Input, Output : mV, Ohm) |
Comparison with Multi-Product Calibrator | In-house/On-site | |
Temperature calibrator (Input, Output : mV, Ohm) |
Comparison with Multi-Product Calibrator | In-house/On-site | |
AC/DC wattmeter (Single phase) Digital 11 kw Analog 11 kw |
Comparison with Multi-Product Calibrator | In-house/On-site |
Plastic & Rubber Tester Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
TESTING MACHINE | Melt Flow Indexer |
In-house method base on ASTM D1238 and ISO1133 |
On-site |
- Temperature Up to 300 C - Die Length & Outside diameter Up to 10 mm - Piston Diameter Up to 10 mm |
|||
- Weight of Piston Up to 110 g - Head of Length Up to 7 mm - Reference mark Up to 30 mm -Weight Up to 10 kg -Time Up to 180 sec |
In-house method base on ASTM D648 and ASTM D1525 | On-site | |
HDT-Vicat Tester - Temperature - Dimension - Weight Set - Temp Rate - Displacement Reading |
In-house method base on ASTM F2029 | On-site | |
Heat Seal Tester - Temperature - Pressure - Timer |
In-house method base on ASTM D1894 |
On-site | |
Friction Tester - Sled weight - Load cell - Speed |
In-house method based on ISO13802 : 1999 |
On-site | |
Pendulum Impact -Velocity -Angle |
Chemical Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
CHEMICAL | pH meter Nominal pH |
In-house method base on ASTM E70-07 |
In-house |
4 7 10 |
Volume Laboratory
Field of |
Parameter/Range/Item |
Standard/Technic Method |
Laboratory status |
VOLUME | Micro pipette Up to 100μl | In-house method base on ISO 8655-6 : 2002 (E) |
In-house |
>100μl to 200μl | |||
>200μl to 500μl | |||
>500μl to 1000μl | |||
>1000μl to 5000μl | |||
>5000μl to 10000μl | |||
Volumetric flask 1ml to 2000ml |
In-house method base on ASTM E542 :2001 |
In-house | |
Mechanical metrology instruments |
|||
MECHANICAL | Viscometer (Dynamicrotation) |
In-house method by comparison with certified viscosity standard |
In-house |
100 cps 500 cps 5000 cps |